Open Tools · Electrical: electronics, embedded, instrumentation and lighting
Loopsheet: free online instrument loop calculator
Free · no sign-up
Work out an instrument signal or a loop voltage budget, then keep the assumptions with its tag and service. Loopsheet scales a process value to a 4–20 mA current and back (linear, reverse-acting or square-root), checks whether the supply can drive the transmitter through the cable and receiver resistances, and converts thermocouple voltage and temperature with the cold junction handled for you.
Your own sensor data stays under your control: enter the constants of a platinum RTD or a monotone sensor table from your datasheet, and the tool says plainly that they are user-entered. Records save as open JSON, results export as CSV, and the Loop sheet prints as a one-page table. The Guide states the limits, and the Verify page runs the reference cases in your browser, including values read from published thermocouple tables.
What Loopsheet can do
- Scale process values to and from 4–20 mA, reverse range and square-root flow included
- Check a series loop voltage margin and the largest allowable resistance
- Convert type J, K and T thermocouple voltage and temperature with a cold junction
- Convert a custom RTD or a user-entered sensor table in both directions
- Compare observed currents with expected values against your own tolerance
- Save JSON records, export CSV, SVG and PNG, and print a loop sheet
How we verify Loopsheet
Loopsheet is checked against 11 reference cases. Where a reference answer exists you can run every check yourself on the Verify page, and the Loopsheet user guide documents every feature and limitation.
The Verify page runs the tool's reference cases in your browser, using the same inputs, references and finite-tolerance evaluator as the automated test suite. Cases identify their basis and reference family. Hand-derived scaling examples, Kirchhoff voltage/energy balances, independent derivative integration for the custom RTD, and determinant-based table interpolation check the implementation. Published thermocouple checks use separately printed fixed-point values from NIST Monograph 175, rather than recomputing the coefficient polynomial as its own oracle.
Loopsheet is part of Open Tools, the free engineering tools that run in your browser.
Professional use. Results are for education and preliminary design. They must be checked by a qualified professional, and they are not a substitute for code-compliant design or licensed engineering judgement.